Diesel generating set GMP1250

Diesel generating set GMP1250

  • Photo of diesel genset GMP1250.
  • Photo of diesel genset GMP1250.

General specifications

Max power 1250 kVA / 1000 kW
Cont power 1125 kVA / 900 kW

Engine specifications

Type Perkins
Model 4008-30TAG3
Cooling water-cooled
Rate speed 1500 rpm
Engine start electric starting
Fuel consumption @ 70% (prime) 159.8 l/h

Alternator specifications

Type Leroy Somer
Model LSA 50.2 M6
Phase 3
Voltage 230/400 V, 50 Hz
Protection IP23

Type Stamford
Model HCI6K
Phase 3
Voltage 230/400 V, 50 Hz
Protection IP23
Type Mecc Alte
Model ECO 43-2M/4
Phase 3
Voltage 230/400 V, 50 Hz
Protection IP23

Control panel

Model GMCA20-04

Dimensions

Open set
Dimensions, LхWхH 4450×2200×2260 mm
Weight 9250 kg
Note: exterior and technical data are subject to change

A complete set configuration can be made to custom order with required specifications (a combination of the engine, generator, control panel, power parameters, dimensions, noise muffling level, fuel tank size, etc.).