Professional Series

Professional power systems suit for long-term operation due to the enlarged capacity of the fuel tank and additional control tools. Supplied open-type with air cooling. The model with electric start is also equipped with 12 V accumulator battery. The solid welded frame ensures durability of the generator set’s operation and makes application thereof more convenient.

Additional options can include a set of demountable wheels, electromagnetic valve, which controls fuel supply, as well as the auto start system with automatic transfer switch.

Model Power Start Engine Tank
l
Sizes
mm
Weight
kg
PDF
kVA kW Brand Type Cons.70%
l/h
1-phase, 230 V
GMY4500ELX 4.4 3.5 E Yanmar L70AE 0.8 20 780×520×560 79 Request
GMY4500LX 4.4 3.5 M Yanmar L70AE 0.8 20 780×520×560 72 Request
GML5000ELX 4.6 3.7 E KOHLER KD15-350 1.1 20 780×520×560 82 Request
GML5000LX 4.6 3.7 M KOHLER KD15-350 1.1 20 780×520×560 75 Request
GMK5000ELX 5 5 E KOHLER KD15-440 1.2 12 760×540×740 130 Request
GMY7000ELX 6.3 5 E Yanmar L100AE 1.3 20 990×560×690 123 Request
GMY7000LX 6.3 5 M Yanmar L100AE 1.3 20 990×560×690 116 Request
GML7500ELX 7 5.6 E KOHLER KD15-440 1.5 20 750×560×620 116 Request
GML7500LX 7 5.6 M KOHLER KD15-440 1.5 20 750×560×620 109 Request
GMXD6500ELX 6.3 6.3 E G-Drive DE0498I-E 1.5 15 810×550×610 105 Request
GML9000ELX 9 7.2 E KOHLER KD330-2 2.1 20 990×560×690 150 Request
GMXD8500ELX 8.5 8.5 E G-Drive DE0678I-E 2.1 15 810×590×730 130 Request
GML11000ELX 11 8.8 E KOHLER KD425-2 2.2 20 990×560×690 160 Request
GML13000ELX 13 10.4 E KOHLER KD477-2 3.1 20 990×560×690 215 Request
GMXD13000ELX 13 13 E G-Drive DE0997I-VE 2.9 22.5 1060×670×750 195 Request
3-phase, 400/230 V
GMY4500TELX 4.4 3.5 E Yanmar L70AE 0.8 20 780×520×560 79 Request
GMY4500TLX 4.4 3.5 M Yanmar L70AE 0.8 20 780×520×560 72 Request
GML5000TELX 4.6 3.7 E KOHLER KD15-350 1.1 20 780×520×560 82 Request
GML5000TLX 4.6 3.7 M KOHLER KD15-350 1.1 20 780×520×560 75 Request
GMY7000TELX 6.3 5 E Yanmar L100AE 1.3 20 990×560×690 128 Request
GMY7000TLX 6.3 5 M Yanmar L100AE 1.3 20 990×560×690 121 Request
GML7500TELX 7.3 5.8 E KOHLER KD15-440 1.5 20 750×560×620 121 Request
GML7500TLX 7.3 5.8 M KOHLER KD15-440 1.5 20 750×560×620 114 Request
GML9000TELX 9 7.2 E KOHLER KD330-2 2.1 20 990×560×690 155 Request
GML11000TELX 11 8.8 E KOHLER KD425-2 2.2 20 990×560×690 160 Request
GML13000TELX 13.3 10.6 E KOHLER KD477-2 3.1 20 990×560×690 215 Request
GML22R 21 16.8 E KOHLER KD625-2 4.6 52 1150×700×850 270 Request
Note: exterior and technical data are subject to change

A complete set configuration can be made to custom order with required specifications (a combination of the engine, generator, control panel, power parameters, dimensions, noise muffling level, fuel tank size, etc.).